上海天沐自动化仪表有限公司
上海天沐自动化仪表有限公司

 

 

 
 
Shanghai TM Automation Instruments Co.,Ltd.- Product  
 

 NS-WL2 Load Cell
 
    SPECIFICATIONS  
 Technical parameters
Unit
Specifications
 Rated load
t
0.1,0.5,1,5,8,10,20…150
 Rated output
mV/V
2.0±0.01
 Non-linearity
%F.S
≤±0.05
 Hysteresis
%F.S
≤±0.05
 Repeatability
%F.S
≤±0.03
 Zero output
%F.S
<±1
 Zero temperature coefficient
%F.S/℃
≤0.005
 Insulation resistance 
≥2000
 Bridge voltage
VDC
10
 Operating temperature range -20~+70
 Permission overload
%F.S
150
 Remarks
Can be designed in 12VDC or 24VDC supply    0~5V or 4~20mA output

Rang(Kg)\Size(mm)
H
φ
M
A
0.1~0.7
88
44
16×1.5
58
1~5
120
63
22×2.5
68
7~15
138
76
30×3.5
94
20
156
88
36×3
108
30~150
Size customized
    PHYSICAL DIMENSION  
 
 
 
 
 
 
 